Requirements for folding physical and chemical indicators
The physical and chemical indicators such as the content of effective ingredients and pH value of disinfectants should comply with relevant standards for product quality. Peroxyacetic acid should comply with GB 19104, and hydrogen peroxide should comply with the requirements of GB 1616.
Stability requirements: The effective ingredient reduction rate of liquid disinfectants within the product validity period should be ≤ 15%; The decrease rate of effective ingredient content of solid disinfectants within the product’s validity period is ≤ 10%.
The residual toxicity after disinfection and in the environment should comply with the requirements of relevant national standards and regulations.
During the disinfection process, it is not prone to combustion, explosion
Requirements for folding to kill microorganisms
In laboratory sterilization test or disinfection simulation field test, when aerosol spray method is used for disinfection, the amount of disinfectant shall be ≤ 10 mL/m. Under the conditions of 20 ℃~25 ℃ and relative humidity of 50%~70%, the effect is ≤ 1 hour. The killing rate of Staphylococcus aureus in the air should be ≥ 99.9%.
Under natural conditions on site, when aerosol spray method is used for disinfection, the amount of disinfectant shall be ≤ 10 mL/m. When the action is ≤ 1 hour, the extinction rate of natural bacteria in the air should be ≥ 90.0%
Safety requirements for folding toxicology
Acute oral toxicity is actually non-toxic
Acute inhalation toxicity is actually non-toxic.
The mutagenicity test was negative.